NFPA 70 National Electrical Code (NEC)

ID 6882 | | Visite: 9555 | Documenti normazione ENTIPermalink: https://www.certifico.com/id/6882

NFPA 70   National Electrical Code 2017

NFPA 70 National Electrical Code (NEC)

Ed. 2017

Adopted in all 50 states, the NEC is the benchmark for safe electrical design, installation, and inspection to protect people and property from electrical hazards.

90.2 Scope. 
(A) Covered. This Code covers the installation and removal of electrical conductors, equipment, and raceways; signaling and communications conductors, equipment, and raceways; and optical fiber cables and raceways for the following:
(1) Public and private premises, including buildings, structures, mobile homes, recreational vehicles, and floating buildings
(2) Yards, lots, parking lots, carnivals, and industrial substations
(3) Installations of conductors and equipment that connect to the supply of electricity
(4) Installations used by the electric utility, such as office buildings, warehouses, garages, machine shops, and recreational buildings, that are not an integral part of a generating plant, substation, or control center
(B) Not Covered. This Code does not cover the following:
(1) Installations in ships, watercraft other than floating buildings, railway rolling stock, aircraft, or automotive vehicles other than mobile homes and recreational vehicles
Informational Note: Although the scope of this Code indicates that the Code does not cover installations in ships, portions of this Code are incorporated by reference into Title 46, Code of
Federal Regulations, Parts 110–113.
(2) Installations underground in mines and self-propelled mobile surface mining machinery and its attendant electrical trailing cable
(3) Installations of railways for generation, transformation, transmission, energy storage, or distribution of power used exclusively for operation of rolling stock or installations used exclusively for signaling and communications purposes
(4) Installations of communications equipment under the exclusive control of communications utilities located outdoors or in building spaces used exclusively for such installations
(5) Installations under the exclusive control of an electric utility where such installations
a. Consist of service drops or service laterals, and associated metering, or
b. Are on property owned or leased by the electric utility for the purpose of communications, metering, generation, control, transformation, transmission, energy storage, or distribution of electric energy, or
c. Are located in legally established easements or rights-of-way, or
d. Are located by other written agreements either designated by or recognized by public service commissions, utility commissions, or other regulatory agencies having jurisdiction for such installations. These written agreements shall be limited to installations for the purpose of communications, metering, generation, control, transformation, transmission, energy storage, or distribution of electric energy where legally established easements or rights-of-way cannot be obtained. These installations shall be limited to federal lands, Native American reservations through the U.S. Department of the Interior Bureau of Indian Affairs, military bases, lands controlled by port authorities and state agencies and departments, and lands owned by railroads.
Informational Note to (4) and (5): Examples of utilities may include those entities that are typically designated or recognized by governmental law or regulation by public service/utility commissions and that install, operate, and maintain electric supply (such as generation, transmission, or distribution systems) or communications systems (such as telephone, CATV,
Internet, satellite, or data services). Utilities may be subject to compliance with codes and standards covering their regulated activities as adopted under governmental law or regulation.
Additional information can be found through consultation with the appropriate governmental bodies, such as state regulatory commissions, the Federal Energy Regulatory Commission, and the Federal Communications Commission.
(C) Special Permission. The authority having jurisdiction for enforcing this Code may grant exception for the installation of conductors and equipment that are not under the exclusive control of the electric utilities and are used to connect the electric utility supply system to the service conductors of the premises served, provided such installations are outside a building or structure, or terminate inside at a readily accessible location nearest the point of entrance of the service conductors.

NFPA 2018

Descrizione Livello Dimensione Downloads
Allegato riservato NFPA 70 - National Electrical Code 2017.pdf
NFPA 2018
7248 kB 29

Tags: Normazione Abbonati Normazione NFPA

Ultimi archiviati Marcatura CE

Mag 13, 2025 721

Circolare Ministero dell'Interno 29 agosto 2005

Circolare Ministero dell'Interno del 29 agosto 2005 ID 23969 | 13.05.2025 / In allegato Circolare Ministero dell'Interno del 29 agosto 2005Decreto legge 27 luglio 2005, n. 144, recante misure urgenti per il contrasto del terrorismo internazionale, convertito con modificazioni dalla legge 31 luglio… Leggi tutto
Decreto Legislativo 29 dicembre 1992 n  517
Apr 25, 2025 896

Decreto Legislativo 29 dicembre 1992 n. 517

Decreto Legislativo 29 dicembre 1992 n. 517 / Strumenti per pesare a funzionamento non automatico ID 23880 | 25.04.2025 Decreto Legislativo 29 dicembre 1992 n. 517Attuazione della direttiva 90/384/CEE in materia di strumenti per pesare a funzionamento non automatico, codificata nella direttiva… Leggi tutto
Apr 25, 2025 824

Direttiva delegata (UE) 2015/13

Direttiva delegata (UE) 2015/13 ID 23879 | 25.04.2025 Direttiva delegata (UE) 2015/13 della Commissione, del 31 ottobre 2014, che modifica l'allegato III della direttiva 2014/32/UE del Parlamento europeo e del Consiglio, per quanto riguarda il campo di portata dei contatori dell'acqua. (GU L 3 del… Leggi tutto
Guidance on Dock shelters
Apr 23, 2025 809

Guidance on Dock shelters

Guidance on Dock shelters (FEM - October 2024) ID 23864 | 23.04.2025 / Attached Intention of this Guideline To provide users, architects, contractors and suppliers with an awareness of the benefits and specific characteristics of the different Dock shelter types used in the loading dock area.A dock… Leggi tutto
Apr 01, 2025 896

Decreto Dirigenziale n. 40 del 14.03.2025

Decreto Dirigenziale n. 40 del 14.03.2025 ID 23718 | 31.03.2025 Nuovi programma e modalità d'esame per il conseguimento del titolo professionale di ufficiale di navigazione del diporto di 2a classe, ai sensi dell’articolo 4-bis, comma 2, lettera h), del decreto del Ministero delle infrastrutture e… Leggi tutto
Cambiamenti ambientali globali e dispositivi medici
Feb 18, 2025 502

Cambiamenti ambientali globali e dispositivi medici: un primo studio integrato

Cambiamenti ambientali globali e dispositivi medici: un primo studio integrato ID 23848 | 18.02.2025 / In allegato L’Istituto Superiore di Sanità, su richiesta del Ministero della Salute, ha effettuato uno studio sul ruolo che i dispositivi medici possono ricoprire nella mitigazione degli effetti… Leggi tutto

Più letti Marcatura CE

Dic 18, 2024 124776

Regolamento Prodotti da Costruzione (UE) 305/2011 - CPR

Regolamento CPR (UE) 305/2011 ID 518 | Update news 18.12.2024 / In allegato Regolamento (UE) N. 305/2011 del Parlamento Europeo e del Consiglio del 9 marzo 2011 che fissa condizioni armonizzate per la commercializzazione dei prodotti da costruzione e che abroga la direttiva 89/106/CEE del… Leggi tutto