General Safety and Performance Requirements (Annex I) MDR

ID 11161 | | Visite: 5109 | Documenti Marcatura CE UEPermalink: https://www.certifico.com/id/11161

General Safety and Performance Requirements  Annex I  MDR

General Safety and Performance Requirements (Annex I) in the New Medical Device Regulation

Comparison with the Essential Requirements of the Medical Device Directive and Active Implantable Device Directive

As compliance with the ‘Essential Requirements (ERs)’ is the keystone for establishing conformity with the Medical Device Directive (MDD, 93/42/EEC) and Active Implantable Medical Device Directive (AIMDD, 90/385/EEC), so too is compliance with the ‘General Safety and Performance Requirements (SPRs)’ in establishing conformity with the recently published Medical Device Regulation – EU Regulation 2017/745 (MDR). The Regulation’s date of publication was 5 May 2017 and date for Entry into Force was 25 May 2017 with a 3-year transition period (postponed 25 May 2021).

The purpose of this white paper is to compare the ERs in the MDD and AIMDD to the SPRs in Annex I of the new MDR. Where there are 13 ERs in the MDD and 16 in the AIMDD, there are 23 SPRs in the new MDR. The overall text and requirements are expanded, but the scope and topics are consistent overall with the previous directives with a few notable exceptions. Some topics such as clinical evaluation and medicinal consultation have moved from the requirements list into the articles, while other topics are new to the requirements list, including devices without a medical purpose and requirements for devices used by lay persons. A number of areas now have increased emphasis and more explicit requirements, which in many cases align with harmonized standards and industry guidances. Importantly, all of these points will now become European law under this Regulation.

The areas in Annex I considered to have highest impact to manufacturers are: 

- medicinal substances (and substances absorbed or locally dispersed); 
- devices incorporating materials of biological origin; 
- substances of concern; 
- labelling requirements; 
- emphasis on cybersecurity.

Other key areas of impact in the MDR outside Annex I include:

- clinical data and evaluation requirements;
- reclassification of some device types;
- post-market requirements.

These topics outside Annex I are beyond the scope of the current white paper, but manufacturers should be aware that these important areas are also changing in comparison to the directives. An updated white paper will follow focusing on the implications of the MDR and MEDDEV 2.7.1 Rev. 4 for clinical data and evaluation.

The paper is organized in order of the new safety and performance requirements by number, with the goal that the readers begin to become familiar with the new numbering and organization. The intent is not to reproduce each requirement, but to highlight areas of particular similarity and difference between the ERs and SPRs.

While many of the SPRs (namely numbers 10-23) have explicit headings or titles, others have been added here in an attempt to highlight the theme of each requirement. Cross-references to ERs and other documents with similar text have been identified for each requirement.

In addition, each SPR has been graded (low, medium or high) relative to the expected impact of the changes to the manufacturer (see Appendix 1 for SPR/ER Cross-reference Mapping Guide). Understanding the SPRs will be an important aspect of manufacturers’ transition plans from the directives to the MDR.

Add more in attachment

Collegati

Descrizione Livello Dimensione Downloads
Allegato riservato General Safety and Performance Requirements (Annex I) MDR.pdf
BSI 2017
228 kB 13

Tags: Marcatura CE Regolamento Dispositivi Medici

Ultimi archiviati Chemicals

Relazione annuale 2025 del Direttore dell ISIN al Governo e al Parlamento
Lug 15, 2025 95

Relazione annuale 2025 del Direttore dell’ISIN al Governo e al Parlamento

Relazione annuale 2025 del Direttore dell’ISIN al Governo e al Parlamento ID 24282 | 15.07.2025 / In allegato Relazione annuale del Direttore dell'ISIN al Governo e al Parlamento sulle attività svolte dall'ISIN e sullo stato della sicurezza nucleare nel territorio nazionale 2025 Il documento fa… Leggi tutto
Lug 03, 2025 592

Regolamento (Euratom) 2021/765

Regolamento (Euratom) 2021/765 ID 24219 | 03.07.2025 Regolamento (Euratom) 2021/765 del Consiglio del 10 maggio 2021 che istituisce il programma di ricerca e formazione della Comunità europea dell'energia atomica per il periodo 2021-2025 che integra il programma quadro di ricerca e innovazione… Leggi tutto
Lug 03, 2025 601

Regolamento (Euratom) 2025/1304

 Regolamento (Euratom) 2025/1304 ID 24218 | 03.07.2025 Regolamento (Euratom) 2025/1304 del Consiglio, del 23 giugno 2025, che istituisce il programma di ricerca e formazione della Comunità europea dell’energia atomica per il periodo 2026-2027 che integra il programma quadro di ricerca e innovazione… Leggi tutto
ECHA compendium of analytical methods
Giu 27, 2025 794

ECHA compendium of analytical methods for enforcing REACH restrictions - Ed. 3.0 2025

ECHA compendium of analytical methods for enforcing REACH restrictions - Ed. 3.0 2025 ID 24178 | 27.06.2025 / Attached ECHA has updated its compendium of analytical methods to help authorities to enforce and companies to comply with REACH restrictions. The compendium consists of a collection of… Leggi tutto

Più letti Chemicals

Notifica HACCP
Apr 05, 2022 103794

Notifica ai fini registrazione Regolamento CE n. 852/2004

Notifica ai fini della registrazione (Reg. CE n. 852/2004) - Ex notifica sanitaria alimentare ID 7901 | 06.03.2019 / Modello notifica allegato [panel]Regolamento (CE) 852/2004...Articolo 6 Controlli ufficiali, registrazione e riconoscimento 1. Gli operatori del settore alimentare collaborano con le… Leggi tutto